Sterilization of Dental and Medical Instruments in the Statim 2000S and 5000S Cassette Autoclaves

Larger than the 2000, the Statim 5000 has an additional sterilization cycle and a roomier cassette designed to process bulkier instruments and greater loads. It's a reliable cassette sterilizer that's compact enough to fit in patient treatment areas and fast enough to sterilize expensive Lasik, PRK, endoscopic and cataract instruments, including phaco handpieces, between procedures - it can complete an unwrapped sterilization cycle in just nine minutes and a wrapped cycle in just 17.5 minutes.*

The Statim 5000 is fully automatic. Simply select one of four sterilization programs and with a single touch of the keypad, begin the cycle. An advanced microprocessor controls all functions and maintains optimal sterilization conditions, from start to finish.

SciCan's Statim cassette sterilizers have a biological effectiveness that has been proven in tests for hollow and solid instruments at many internationally recognized institutes in Canada, the United States and Europe.

The Certainty Of Validation

The Statim S-cycle cassette autoclave is a bespoke steriliser in that it is validated microbiologically by independent research institutes and tested for specific instruments. These include all major brands of handpieces.

Now you can also obtain daily validation of Statim’s sterilisation cycle with a specifically designed Process Challenge Device – StatimHelix that makes Statim an S class autoclave that can prove its effectiveness by both biological and mechanical means.

And with daily validation, you can be certain that Statim is meeting the challenge of ensuring that yourself, your staff and your patients are protected against cross-infection from contaminated instruments.

Statim also validates its own successful cycle. A computerized microprocessor aborts the cycle if any of the parameters of temperature, pressure or time are not achieved. You can be certain that by following the simple keypad instructions the fully automatic operation will result in sterilisation of all your solid, hollow, wrapped or unwrapped instruments.

Easy To Use And Maintain

Very simple keypad operation and helpful LED display prompts makes Statim S-cycle cassette autoclaves easy to use and user friendly.

Statim is also self-diagnosing – if a problem occurs it will immediately be indicated on the electronic display panel… very reassuring.
Start
Stop
Level Indicator
One touch begins the sterilization process. Manual override allows safe interruptio at any stage of the process. A cleverly designed spirit level indicator assures set-up and completely safe operation.

The Statim Difference
Attractive, compact, reliable and gentle

Statim’s steam injector system provides temperature consistency and expels the air that causes oxidation in conventional autoclaves. Statim cassette autoclaves use only clean distilled water with every cycle, preventing the formation of rust and the build-up of bio contaminants. Also, a built-in air pump flushes the chamber with filtered dry air, further reducing humidity.

Light, thin-walled Statim cassettes promote rapid heating and cooling, further minimising overall processing time and reducing instrument exposure to heat. All designed to maximise the useful life of your valuable instruments and to minimize maintenance costs.

Ultra-thin walled cassettes allow for rapid heating and cooling. Precision inlet/outlet system for quick, thorough steam injection and air purging. Schematic of forced air removal design with combined purging.

Very simple operation. Just select the cycle and press start. That’s all there is to it! Accurate record keeping and tracking is provided by the Statim 5000 integral printer or an optional external printer for Statim 2000 An important biological filter will not allow bacteria or spores above 0.3 µm to enter the sterilising chamber during the drying cycle. An efficient air filtration system includes easy access filters for quick replacement

Order Code Accessories for Statim 2000/5000
01-100008A Cassette for Statim 2000
01-101613S Cassette for Statim 5000
01-100028S Cassette Seal for Statim 2000
01-101649S Cassette Seal for Statim 5000
01-101657S Thermal Paper (Box of 10 rolls)
01-108341 StatimHelix Test Device
99-108332 Sterilisation Emulator 134°C 3.5 min (250pcs)
20ZPLUS STAT-DRI 2 oz.
01-102119S Biological Air Filter
01-108262S Instrument Basket for Statim 2000
01-108263S Instrument Basket for Statim 5000

Specifications table for: Statim 2000 Statim 5000
Machine Dimensions: Length: 48.5 cm 55 cm
Width: 41.5 cm 41.5 cm
Height: 15 cm 19 cm
Cassette Size (External):
(Includes Handles)
Length: 41 cm 49.5 cm
Width: 19.5 cm 19.5 cm
Height: 4 cm 8 cm
Cassette Size (Internal): Length: 28 cm 38 cm
Width: 18 cm 18 cm
Height: 4 cm 8 cm
Sterlisation Chamber Volume: 1.8 l 5.1 l
Reservoir Volume: 4.0 l 4.0 l
Weight (Withough Water): 21 Kg 33 Kg
Clearance required: Top: 50 mm 50 mm
Sides: 50 mm 50 mm
Back: 50 mm 50 mm
Front: 48 cm 57 cm
Clearance required to remove cassette: 48 cm 57 cm
Minimum charge in the water resevoir: 550 ml 550 ml
PRV value (pressure relief valve): 3 BAR 3 BAR
Electrical Rating: 220 - 240V, 50Hz, 6A 220 - 240V, 50Hz, 6A
Current: AC AC
Protection Class: I I
Protection: Covered Covered
Ambient Operating Temperature: 5°C - 40°C 5°C - 40°C
Sound Levels: Mean - 56 dB
Peak - 65 dB
Mean - 56 dB
Peak - 65 dB
Humidity: 80% Max. 80% Max.
Max. Altitude: 2000 m 2000 m
Optional printer Statim 2000/5000
Type: Thermal Printer
Print: 20 characters per line
Print Speed: 1 line per second
Paper Roll Capacity:
approx.
80 sterilisation cycles per roll



more info


   