The Hydrim M2 washer disinfector.
Perfectly prepares instruments for sterilisation.
|
 |
|
|
If it isn’t clean? It can’t be sterilised!
|
Authorities now recommend that instruments must first be processed in a mechanical washer or washer-disinfector prior to sterilisation. Across Europe, standards and guidelines (EN15883 / RKI / BDA Advice Sheet A12) reflect this advice.
Effective sterilisation begins with the Hydrim M2 washer disinfector which automatically washes, rinses, disinfects and dries instruments, simply by pressing a button on the keypad.
The Hydrim M2 is manufactured in Germany by BHT Hygienetechnik to the highest standards.
|
|
Safer For Your Staff
|
Integrating mechanical washing into the practice decontamination protocol provides a high level of safety, particularly against the risk of skin puncture injuries which occur during the hand washing, rinsing and patting dry of contaminated instruments. Hydrim eliminates the soaking, scrubbing and rinsing associated with traditional pre-sterilisation processes. Disinfection at 93?C for ten minutes following the washing phase renders the instruments safe to handle.
The chemicals in ultrasonic baths are typically changed once per day. Microbial load builds throughout the day and instruments are often cleaned for variable periods of time. In contrast, mechanical washing in the Hydrim is more efficient than an ultrasonic bath because Hydrim is consistent, more powerful and uses only single-use water and detergent chemicals.
|
|
Kinder to your instruments
|
Hydrim Cleaning Solution with instrument protection (HIP) has been formulated to achieve excellent cleaning results while assuring exceptional compatibility with a wide range of metals and coatings used in dental instruments. Your valuable instruments will be protected better and for longer by the HIP formulation. SciCan’s patented HIP cleaning solution, combined with Hydrim’s specially designed wash programme, provides a superior washing system which perfectly prepares your instruments for sterilisation with a Statim, Quantim or other sterilising process.
|
PREWASH <45ºC
|
A small amount is dosed, with the water, in the pre-wash portion of the chosen cycle. Exposed portions of the instruments are therefore instantly protected. As organic matter is removed from the instrument during the cycle, newly exposed areas of the instrument become protected as they are exposed. |
WASH 50ºC
|
The main dose of HIP is dispensed during the main hot wash portion of the cycle where it then continuously removes the more stubborn organic materials and continues to protect the instruments. |
RINSE/DISINFECT 60ºC-93ºC
|
Finally, a further small amount of HIP is dosed in with the rinse or disinfect portion of the cycle to ensure continuing protection at all times that the instruments are exposed to water. |
DRY
|
During the drying cycle, as the water is evaporating from the instruments, HIP protects the instruments from corrosion in the moist, oxygen-rich chamber. |
|
Liquid chemical dosing system
|
The HIP solution is kinder to your instruments and to the Hydrim unit itself, as the liquid detergent rapidly and fully disperses, unlike powder detergent which can form clumps and compromise the efficiency of the washing process.
HIP is very accurately dosed by a membrane pump. The amount of chemical and the temperature at which is it dosed are controlled by advanced software.
A sensor ensures that there is sufficient chemical to complete the cycle. If there is insufficient chemical, the Hydrim will not start.
|
|
Built In Dryer
|
|
Drying of instruments after cleaning, and before wrapping, is recommended by major instrument manufacturers to prevent corrosion. The Hydrim M2 has an active drying system that circulates warm air throughout the chamber following the disinfection cycle. A built-in dryer with Hepa filter ensures that instruments are dried with air free of contaminants.
|
|
Record Keeping
|
|
A choice of datalogger or printer is available to keep full process records to meet the documentation needs of the practice.
|
|
Datalogger
A datalogger, designed for use with the Hydrim M2, is available as an optional accessory.
|
|
Printer
The RS232 9 pin port offers the user the option to connect the Hydrim M2 to a selection of standard printers.
|
|
Independent Monitoring
|
|
|
Complying with the requirements of EN15883, the Hydrim M2 offers independent monitoring of temperature, pump pressure and cleaning solution flow resulting in error codes when problems occur.
|
|
|
Flexible Configurations
|
|
Whether instruments are placed in cassettes or trays, or processed loose in baskets, Hydrim can be easily configured to meet the practice requirements. As a guide the Hydrim M2 can process about 100 instrument sets in an 8 hour day.
|
| Cycle |
P1 |
P2 |
| Pre-wash |
<45°C 3 min |
<45°C 3 min |
| Wash |
50°C 5 min |
50°C 5 min |
| Disinfect |
80°C 10 min |
93°C 10 min |
| Dry |
10 min |
10 min |
| Total time* without drying |
approx. 60 min |
approx. 70 min |
| Water consumption |
24L |
24L |
| *Cycle times depend on the temperature and pressure of incoming water |
 |
 |
 |
Hinged instrument rack 15793.00 192 x 100 x 109 mm
|
Basket with hinged lid, 1/4 size 01-109966S 159 x 216 x 54 mm
|
Hygiene basket, 1/4 size 01-109967S 159 x 216 x 44 mm
|
 |
 |
 |
Statim 2000 basket 01-107240 275 x 178 x 42
|
Statim 5000 basket 01-107241 373 x 178 x 42mm
|
Long basket 01-108232 442 x 150 x 42 mm
|
 |
 |
 |
Cleaning Solution Bottle CS-HIPL
|
5-cassette rack, full size 01-109963S 480 x 355 x 158 mm
|
5-cassette rack, half-size 01-109964S 480 x 168 x 158 mm
|
 |
 |
 |
Rack for 3 cassettes 15470.01
|
Insert for 8 half-trays 15469.00
|
Rack for vertical instruments 15555.00/01
|
 |
 |
 |
Medical basket with handles, B 01-108262S
|
Medical basket with handles, C 01-108263S
|
SYS-TM Instrument Cassettes SYS-TM1 – 178 x 64 x 13 mm SYS-TM2 – 178 x 64 x 25 mm SYS-TM3 – 178 x 114 x 13 mm SYS-TM4B – 267 x 165 x 25 mm
|
| Hydrim Technical Specifications |
M2 |
| Overall product width |
600 mm |
| Overall product height |
850 mm |
| Overall product length |
600 mm |
| Length with door open |
1200 mm |
| Unpacked weight |
85kg (max) |
| Water softener |
Standard |
| Running noise |
60dB (A) |
| Drying system |
Blower |
| Hot and cold water connections |
G ¾”/ NPT |
| Drain |
¾”/ DN 20 |
| Inlet water pressure |
2 - 5 bar |
| Electrical connections |
220-240V, 50Hz, 16 amp |
| Independent second temperature sensor |
Standard |
| Independent monitoring of chemical dosing |
Standard |
| Independent monitoring of circulation pump |
Standard |
| RS 232 data port |
Standard |
| Test port |
Standard |
|
The right is reserved to change the specifications and prices of the models and items illustrated and described in this brochure at any time.
|
|
|
|