SciCan SciCan : Canada

Dental Products
Autoclaves
Washing and Disinfection
Dental Handpieces
Dental Handpiece Maintenance
Treatment Instruments
Water Distillers
Treatment Instruments
Medical Products
Tradeshows

Company Profile
Executive Listing
Contact Us





HYDRIM C51w & C51wd
Hydrim Instrument Washers & Washer-Disinfectors.
Perfectly prepares instruments for sterilization in as little as 19 minutes.
Hydrim c51w

Downloads
Safer for your staff, Kinder to your instruments


A Higher Standard
Authorities now recommend that dental instruments must first be processed in a mechanical washer or washer-disinfector prior to sterilisation. Across Europe, standards and guidelines (EN15883 / RKI / BDA Advice Sheet A12) reflect this advice.

Effective sterilisation begins with the Hydrim® C51wd washer disinfector or C51w washer which automatically washes, rinses, disinfects and dries dental instruments, simply by pressing the icons on the touch screen.

The Hydrim process begins with a powerful pre-wash cycle. Then two independent, high-pressure sprays clean the instrument load from above and below removing virtually all organic debris. Cleaning solution is dispensed automatically and clean water is used with every new cycle. Independent tests show the Hydrim to have a protein removal efficacy of 99.9 - 100%.

Hydrim eliminates the soaking, scrubbing and rinsing associated with traditional pre-sterilisation processes. In the C51wd disinfection at 80°C for ten minutes following the washing phase renders the instruments safe to handle.

The chemicals in ultrasonic baths are typically changed once per day. Microbial load builds throughout the day and instruments are often cleaned for variable periods of time. In contrast, mechanical washing in the Hydrim is more efficient than an ultrasonic bath because Hydrim is consistent, more powerful and uses only single-use water and detergent chemicals.

If it isn’t clean? It can’t be sterilised!

Hydrim Cleaning Solution with instrument protection (HIP) has been formulated to achieve excellent cleaning results while assuring exceptional compatibility with a wide range of metals and coatings used in dental instruments. Your valuable instruments will be protected better and for longer by the HIP formulation.

SciCan’s patented HIP cleaning solution, combined with Hydrim’s specially designed wash programme, provides a superior washing system which perfectly prepares your instruments for sterilisation with a Statim, Quantim B2® or other sterilising process.

Active Drying System
Drying of instruments after cleaning, and before wrapping, is recommended by major instrument manufacturers to prevent corrosion . The Hydrim C51w / wd has an active drying system that circulates warm air throughout the chamber following the cycle. In the C51wd, a built-in dryer with Hepa filter (user changeable) ensures that instruments are dried with air free of contaminants. Since instruments are already warm due to the elevated temperature during disinfection, they dry in less than 10 minutes.

The drying time can be extended or reduced if desired.

The drying cycle of the Hydrim eliminates the need for practice staff to pat instruments dry, as they would usually do following manual scrubbing or processing in an ultrasonic cleaner. This further reduces the risk of staff injury, and saves valuable time.

HYDRIM C51wd Cycles
Cycle
P1
Regular Cycle
P2
Heavy Duty Cycle
P3
Heavy Duty Cycle with Disinfection
Description Use for moderately soiled instruments. Use for heavily soiled instruments. Use for heavily soiled instruments and cassettes.
Cold pre-wash <45°C <45°C <45°C
Wash 50°C
5 minutes
50°C
9 minutes
50°C
9 minutes
Rinse/disinfection 60°C 60°C 80°C 10 minutes
Dry 0-15 min. 0-15 min. 0-15 min.
Total time* without drying 19 minutes 23 minutes 45 minutes
Water consumption 13L 13L 13L

HYDRIM C51w Cycles
Cycle
Rinse & Hold
Regular Wash & Dry
Heavy Duty Wash & Dry
Description Use to prevent soil from drying on instruments and if wash cycle is not immediately desired. Use for moderately soiled loose instruments Use for heavily soiled instruments or cassettes or if using the cannula post.
Cold pre-wash <45°C <45°C <45°C
Wash N/A 5 minutes 9 minutes
Rinse/disinfection 60°C 60°C 60°C
Dry N/A 10 minutes
(factory pre-set time).
Can be extended.
10 minutes
(factory pre-set time).
Can be extended.
Total time* without drying 8 minutes 9 minutes 23 minutes
Water consumption 6L 14L 14L

* Cycle times depend on the temperature and pressure of incoming water Hydrim C51 Cycles.

Record Keeping
A datalogger is available as an optional accessory. It connects into an RS232 9 pin port and automatically captures the parameters of the cleaning and disinfection cycle(s) within a text file on a USB stick. Afterwards these files can be saved from the USB stick onto the mainframe computer in the practice.

Datalogger
The RS232 9 pin port offers the user the option to connect to a selection of standard printers.

Accessories

Hinged instrument rack
15793.00
192 x 100 x 109 mm

Large basket
01-108232
442 x 150 x 42 mm

Basket with hinged lid
01-108294
216 x 140 x 54 mm

Hygiene basket
01-108298
203 x 114 x 32 mm

Statim 2000 basket
01-107240
275 x 178 x 42 mm

Statim 5000 basket
01-107241
373 x 178 x 42mm

Support rack
01-108214
350 x 350 x 48 mm

HIP cleaning solution
CS-HIPC
4 x 1.9L

4-cassette rack
01-109153
380 x 385 x 160mm

1-cassette rack
01-107242
388 x 156 x 160 mm

Rack for Vertical Instruments
15555.01

Rack for two cassettes and
two baskets
01-109768S

SYS-TM Instrument Cassettes
SYS-TM1 – 178 x 64 x 13 mm
SYS-TM2 – 178 x 64 x 25 mm
SYS-TM3 – 178 x 114 x 13 mm
SYS-TM4B – 267 x 165 x 25 mm

Specifications
Unit Size: D 460 mm x W 600 mm x H 475 mm
Depth with Door Open: 78 cm
Weight: 35 kg
Running Noise: 60 dBA
Water Softener Standard
Drying system Heater 1kW with Blower
Hot and cold water connections G ¾"/19mm
Drain ¾"/19mm
Inlet water pressure 1-10bar
Electrical Connection: 220-240V, 50Hz, 10 amp
Independent second temperature sensor Standard
Independent monitoring of chemical dosing Standard
Independent monitoring of circulation pumps Standard
RS 232 data port Standard