Quantim 16
Quantim 16 Quantim 16


When a large number of instruments and handpieces need to be sterilized, the Quantim 16 delivers dry, sterile instruments effectively and quickly. It's the ideal larger partner for the more compact Statim series of autoclaves, the fastest autoclaves from start to sterile.

The Quantim 16 Autoclave is designed to address all volume and wrapped sterilization needs. Its large, seamless chamber is 10" in diameter and 13" deep, and holds up to six open instrument trays, three industry standard Hu-Friedy® 8" x 11" instrument cassettes, a pouched instrument rack, or various SciCan SysTM™ instrument cassettes.

With features like its unique safety door, specially designed to open with the touch of a button, its microprocessor-controlled cycle times and temperatures and its front fill and drain capabilities for fast draining of the reservoir when needed, the Quantim 16 is a model of efficient, capable design.

Quantim FAQs

Accessories

Stainless Steel TrayTray Lifter Handle6-Tray Rack
PrinterPouch RackSysTM Instrument Management Cassettes
MICRO FILTER

Specifications

Unit Size : L 440mm x W 480mm x H 410mm
L 17.3" x W 18.9" x H 16.1"
Chamber Capacity : 16 litres / 4.23 U.S. gal
Chamber Diameter : 250mm / 9.8"
Chamber Length : 330mm / 13"
Reservoir Capacity : 3.7 litres / 1 U.S. gal (distilled water)
Weight without water : 42 kg / 93 lbs
Power Consumption : 110V, 60Hz, 1500W

Quantim Autoclave Cleanser

  • Keep your Quantim Running Clean and Effectively

Not only is cleaning your Quantim good clinical practice, it also helps your unit function at peak effectiveness. The Quantim Autoclave Cleanser is designed to clean the reservoir, chamber and tubing of your Quantim. Cleaning the inside of the unit is also very important when sterilizing lubricated instruments to eliminate any oily residue.

SciCan recommends that the reservoir, chamber and tubing be cleaned at least once a week if you are using a recirculating water unit, and monthly for single water use units . or as required with these.

After running a cleaning cycle, empty the remainder of the water reservoir then refill it with distilled water and run a cycle to rinse the system